MTA Endo Repair - Mineral Trioxide Aggregate Powder And Liquid
Original price was: ₹3,000.00.Current price is: ₹1,499.00.50% Off
No ratings yet
Sale!
Brand: Perfect Endo
58% off

Perfect Endo TG6 Rotary File 25mm

0

Original price was: ₹2,000.00.Current price is: ₹842.00.58% Off

Delivery

Categories: , ,
  • Fast Shipping
  • 100% Genuine Product
Share:

Description

About Perfect Endo TG6 Rotary File 25mm

Introducing the Perfect Endo TG6 Rotary File 25mm, the ultimate solution for efficient and precise root canal shaping. This exceptional rotary file system is crafted with high-quality NiTi material and offers a length of 25mm, providing optimal performance for your endodontic procedures. With its remarkable features and advanced design, the Perfect Endo TG6 Rotary File 25mm sets a new gold standard in endodontic file systems.

Unmatched Durability and Flexibility:

The Perfect Endo TG6 Rotary File 25mm undergoes a rigorous heat treatment process, ensuring unparalleled resistance to cyclic fatigue. Compared to traditional MTF files, this innovative system boasts twice the resistance, reducing the risk of file separation and enhancing overall durability. Furthermore, the file’s NiTi composition provides remarkable flexibility, allowing for smooth navigation through curved canals and challenging anatomies.

Optimized Design for Precise Shaping:

Equipped with a set of four different sizes (#V1, #V2, #T1, #T2), the Perfect Endo TG6 Rotary File 25mm offers comprehensive versatility to meet your specific requirements. Each box contains six meticulously crafted pieces, ensuring an ample supply for your professional needs. The rotary files feature specially designed flutes that facilitate efficient debris removal and minimize the risk of distortion or wear, guaranteeing consistent performance throughout your procedures.

Precautions for Safe and Effective Use:

To ensure the best results and maximize the lifespan of your Perfect Endo TG6 Rotary File 25mm, it is essential to follow the recommended precautions:

1. Multiple use disinfection and resterilization cycles may increase the risk of file separation. Exercise caution and consider the appropriate replacement intervals.
2. Avoid immersing the instruments in a sodium hypochlorite solution, as it may affect their performance and durability.
3. Strictly adhere to the manufacturer’s instructions for instrument decontamination to maintain optimal hygiene standards.
4. Adequately irrigate the canal with abundant and frequent irrigation during the procedure to ensure optimal cleaning and disinfection.
5. Establish a reproducible glide path using hand files, preferably at least an Iso 015 size, to facilitate smooth and efficient file insertion.
6. Utilize the Perfect Endo TG6 Rotary File 25mm in a constant rotation at a recommended speed of 300 rpm, applying light apical pressure for optimal performance.
7. Regularly clean the file’s flutes during the procedure and inspect for signs of distortion or wear that may affect its functionality.
8. For enhanced control and precision, it is recommended to use torque control devices during the root canal shaping process.
9. Utilize the Shaping Files (V1, V2, and VO) with a brushing action on the withdrawal stroke to establish a straight line radicular access, ensuring efficient canal shaping.
10. When using the Finishing Files (T1, T2, T3, T4, T5), avoid brushing action and instead focus on passive file movement to follow the canal to the desired working length before immediate withdrawal.

Frequently Asked Questions (FNQs):

Q: How many pieces are included in a box of Perfect Endo TG6 Rotary File 25mm?
A: Each box contains six high-quality rotary files to accommodate your endodontic procedures effectively.

Q: What makes the Perfect Endo TG6 Rotary File 25mm different from other file systems?
A: The Perfect Endo TG6 Rotary File 25mm stands out with its exceptional resistance to cyclic fatigue, twice that of traditional MTF files. Additionally, its NiTi material provides superior flexibility, allowing for efficient navigation through curved canals.

Q: Can I reuse the Perfect Endo TG6 Rotary File 25mm after disinfection?
A: While the files can be reused, it is important to note that multiple disinfection and resterilization cycles may increase the risk of file separation. Please exercise caution and consider appropriate replacement intervals.

Q: Is it necessary to establish a glide path before using these rotary files?
A: Yes, it is recommended to establish a reproducible glide path using hand files, preferably at least an Iso 015 size, to ensure smooth insertion and optimal performance of the Perfect Endo TG6 Rotary File 25mm.

Q: What speed and pressure should I use when using these rotary files?
A: The Perfect Endo TG6 Rotary File 25mm should be used in a constant rotation at a speed of 300 rpm with light apical pressure for optimal results.

Q: Are torque control devices necessary for using these files?
A: While not mandatory, torque control devices are recommended for enhanced control and precision during the root canal shaping process.

Q: How should I clean the files during the procedure?
A: Clean the file’s flutes frequently during the procedure to ensure efficient debris removal and inspect for any signs of distortion or wear that may affect its performance.

Back to top